23 Årgang Industriel eksplosionssikker producent

+86-15957194752 aurorachen@shenhai-ex.com

WhichOneHastheHigherExplosion-ProofLevel,BT4orCT4|Tekniske specifikationer

Tekniske specifikationer

Which One Has the Higher Explosion-Proof Level, BT4 or CT4

The explosion-proof classification of CT4 equipment surpasses that of BT4 equipment.

Klasse og niveauAntændelsestemperatur og gruppe
-T1T2T3T4T5T6
-T>450450≥T>300300≥T>200200≥T>135135≥T>100100≥T>85
jegMetan
IIAEthan, Propan, Acetone, Phenethyl, Ene, Aminobenzen, Toluen, Benzen, Ammoniak, Carbonmonoxid, Ethylacetat, EddikesyreButan, Ethanol, Propylen, Butanol, Eddikesyre, Butyl Ester, Amylacetat EddikesyreanhydridPentan, Hexan, Heptan, Decane, Oktan, Benzin, Hydrogensulfid, Cyclohexan, Benzin, Petroleum, Diesel, PetroleumEther, Acetaldehyd, TrimethylaminEthylnitrit
IIBPropylen, Acetylen, Cyclopropan, Koks ovn gasEpoxy Z-alkan, Epoxy propan, Butadien, EthylenDimethylether, Isopren, HydrogensulfidDiethylether, Dibutylether
IICVand Gas, BrintAcetylenKulstofdisulfidEthylnitrat

BT4 is classified as a Class B temperature group, where the maximum surface temperature of T4-rated devices does not exceed 135°C. CT4 holds a Class C explosion-proof rating, comparable to BT4, and is suitable for environments with hazardous gases such as hydrogen and acetylene, maintaining a maximum surface temperature of 135°C.

Scope of Use

BT4 is suitable for common gases including methane, ethan, petroleum, og brint sulfide.

CT4 encompasses a broader range of less common eksplosiv gasser, such as hydrogen and water gas at the CT1 level, acetylene at the CT2 level, and carbon disulfide at the CT4 level.

Prev:

Næste:

Få et citat ?