Na kato ni veisoliyaki ni cina kei na kebineti e dau yaco mai ena veimataqali ivakaraitaki. Era duidui ena veika e vakayagataki, oka kina na palasitika kaukamea kei na yameyame ni yameyame ni buka; iwalewale ni kena vakacurumi, me vakataka na vertical, lili, vunitaki, se vakacurumi; kei na ivakatagedegede ni idini, oka kina na 380V kei na 220V.
1. GCK, GCS, kei na MNS era sa dua na veisaugear ni livaliva ni lailai.
2. GGD, GDH, kei na PGL e lailai na voltage tudei switchgear kebineti.
3. Na XZW e dua na kato ni veisoliyaki taucoko.
4. Na ZBW e dua na vanua e vakayagataki kina na kato.
5. XL kei na GXL era sa sitoa ni iyaya ni veisoliyaki ni iyaya kei na kato ni taravale; XF me baleta na lewai ni livaliva.
6. Na PZ20 kei na PZ30 ni isoqoni era kato ni veisoliyaki ni cina.
7. PZ40 kei na XDD(R) na kato ni icula livaliva.
8. PXT(R)K-□/□-□/□-□/□-IP□ vakadewataki na kena matailalai me vakaoqo:
1. PXT me baleta na kato ni veisoliyaki e dela ni, (R) me baleta na kena vakacurumi vunitaki.
2. K e vakaraitaka e vica na iwalewale ni wa.
3. □/□ me baleta na kena rated ena gauna oqo/gauna lekaleka e vorata rawa na gauna oqo: k.v., 250/10 e vakaraitaka e dua na kena ivakarau ni 250A kei na dua na gauna lekaleka e vorata na 10kA, which can be reduced as per customer requirements.
4. □/□ for inlet style: □/1 for single-phase input; □/3 for three-phase input; 1/3 for mixed input.
5. □ for outlet circuits: single-phase circuits; three-phase circuits, k.v., 3 iwasewase dua 6 ilakolako, tolu na iwase 3 ilakolako.
6. □/□ for main switch type/protection level; k.v., 1/IP30 for single-phase main switch/IP30 protection; 3/IP30 for three-phase main switch/IP30 protection.
9. Electrical schematic numbers:
1. JL for metering box PXT01 series;
2. CZ for socket box PXT02 series;
3. ZM for lighting box PXT03 series;
4. DL for power box PXT04 series;
5. JC for metering and socket box PXT05 series;
6. JZ for metering and lighting box PXT06 series;
7. JD for metering and power box PXT07 series;
8. ZC for lighting and socket box PXT08 series;
9. DC for power and socket box PXT09 series;
10. DZ for power and lighting box PXT10 series;
11. HH for hybrid function box PXT11 series;
12. ZN for intelligent box PXT12 series.
10. Electrical cabinet naming codes:
AH for high-voltage switchgear;
AM for high-voltage metering cabinet;
AA for high-voltage distribution cabinet;
AJ for high-voltage capacitor cabinet;
AP for low-voltage power distribution cabinet;
AL for low-voltage lighting distribution cabinet;
APE for emergency power distribution cabinet;
ALE for emergency lighting distribution cabinet;
AF for low-voltage load switch cabinet;
ACC or ACP for low-voltage capacitor compensation cabinet;
AD for direct current distribution cabinet;
AS for operation signal cabinet;
AC for control panel cabinet;
AR for relay protection cabinet;
AW for metering cabinet;
AE for excitation cabinet;
ARC for low-voltage leakage circuit breaker cabinet;
AT for dual power source automatic transfer cabinet;
AM for multi-source power distribution cabinet;
AK for knife switch cabinet;
AX for power socket cabinet;
ABC for building automation controller cabinet;
AFC for fire alarm control cabinet;
ABC for equipment monitor cabinet;
ADD for residential wiring cabinet;
ATF for signal amplifier cabinet;
AVP for distributor cabinet; AXT for terminal junction box.
Example of GCK:
The first ‘G’ denotes a distribution cabinet;
The second ‘C’ signifies drawer-type;
The third ‘K’ represents control.
GGD:
The first ‘G’ denotes a distribution cabinet;
The second ‘G’ stands for fixed type;
The third ‘D’ represents power distribution box. Other examples like 1AP2, 2AP1, 3APc, 7AP, 1KX, kei na so tale., are common codes used in engineering distribution systems. These are arranged by designers and aren’t strictly standardized.
Ia, they follow certain patterns, k.v., AL for distribution boxes, AP for power distribution boxes, KX for control boxes, kei na so tale. Me kena ivakaraitaki, 1AL1b indicates a Type B distribution box at Position 1 on the first floor; AT-DT denotes an elevator distribution box; 1AP2 refers to the second position power distribution box on the first floor.