The “abcrepresents gas classifications, categorized into three levels—IIA, IIB, and IIC—according to the maximum experimental safe gap (MESG) or the minimum igniting current (MIC).

ÁstandsflokkurGasflokkunFulltrúar lofttegundirLágmarks íkveikjuneistaorka
Undir námunniégMetan0.280mJ
Verksmiðjur fyrir utan námunaIIAPrópan0.180mJ
IIBEtýlen0.060mJ
IICVetni0.019mJ

Of these, the IIC classification is deemed the most hazardous, with IIB and IIA following in decreasing order of risk. Gases falling under the IIC classification include hydrogen, asetýleni, kolefnisdísúlfíð, ethyl nitrate, and water gas. Those in the IIB category encompass ethylene, coke oven gas, propyne, og vetni sulfide. The IIA classification includes gases such as methane, ethane, bensen, og diesel.