24 Sal Industrial Explosion-Proof Manufacturer

+86-15957194752 aurorachen@shenhai-ex.com

Komkirina Amûrên Elektrîkê yên Teqîn-Delîl

Amûrên elektrîkê yên teqemenî li gorî germahiya herî zêde ya rûyê wan li şeş celeb têne categorîzekirin: T1, T2, T3, T4, T5, û T6. Van kategoriyan ji bo gazên şewitandî bi komên germahiya şewatê re hevaheng in.

Asta germê IEC/EN/GB 3836Germahiya rûyê herî bilind a alavên T [℃]Germahiya lgnition ya maddeyên şewitandinê [℃]
T1450T>450
T2300450≥T>300
T3200300≥T>200
T4135200≥T>135
T5100135≥T>100
T685100≥T>8

The term ‘maximum surface temperaturedenotes the highest temperature that can be reached on the surface or parts of the explosion-proof electrical equipment under both normal and the most adverse conditions deemed acceptable, with the potential to ignite surrounding explosive gas mixtures.

The guiding principle for temperature classification in explosion-proof electrical devices is as follows:

The peak surface germî generated by the device must not be capable of igniting adjacent combustible gases, and it should not exceed the ignition temperature of these gases. For safety ratings, T6 devices rank the highest, while T1 devices are at the lower end.

This demonstrates that for teqîn materials with identical temperatures, it reflects the lower boundary of their ignition temperatures. Berevajî, bo alavên elektrîkê-delîlên teqînê, it denotes the upper limit of their maximum surface temperatures, showcasing a clear distinction in characteristics.

Given that explosion-proof electrical equipment utilized in explosive dust environments clearly states the device’s maximum surface temperature, ew “Electrical Equipment Design Code for Explosive Hazard Environmentsno longer divides explosion-proof electrical equipment into temperature groups.