Taybetmendiyên Teknîkî

Kîjan Asta Teqîn-Delîla Bilindtir e, BT4 an CT4

The explosion-proof classification of CT4 equipment surpasses that of BT4 equipment.

Çîn Û AstaGermahiya Ignition Û Kom
-T1T2T3T4T5T6
-T>450450≥T>300300≥T>200200≥T>135135≥T>100100≥T>85
ezMetan
IIAEthane, Propane, Acetone, Phenethyl, Ene, Aminobenzene, Toluene, Benzene, Amonyak, Qarbon monoksît, Ethyl Acetate, Acetic AcidButane, Etanol, Propylene, Butanol, Acetic Acid, Butyl Ester, Amyl Acetate Acetic AnhydridePentane, Hexane, Heptane, Decane, Octane, Benzîl, Hîdrojen Sulfîdê, Cyclohexane, Benzîl, Kerosene, Diesel, PetroleumEther, Acetaldehyde, TrimethylamineEthyl Nitrite
IIBPropylene, Acetylene, Cyclopropane, Gaza sobeya kokêEpoxy Z-Alkane, Epoxy Propane, Butadiene, EthyleneDimethyl Ether, Isoprene, Hîdrojen SulfîdêDiethylether, Dibutyl Ether
IICGaza avê, HîdrojenAcetyleneKarbon DisulfideEthyl Nitrate

BT4 is classified as a Class B temperature group, where the maximum surface temperature of T4-rated devices does not exceed 135°C. CT4 holds a Class C explosion-proof rating, comparable to BT4, and is suitable for environments with hazardous gases such as hydrogen and acetylene, maintaining a maximum surface temperature of 135°C.

Scope of Use

BT4 is suitable for common gases including methane, etan, petroleum, û hîdrojen sulfide.

CT4 encompasses a broader range of less common teqîn gazên, such as hydrogen and water gas at the CT1 level, acetylene at the CT2 level, and carbon disulfide at the CT4 level.