Technical Parameter
Model and specification | Explosion proof sign | Light Source | Lamp type | Power (W) | Luminous flux (Lm) | Color temperature (K) | Weight (kg) |
---|---|---|---|---|---|---|---|
BPY-□ | Ex db eb IIC T6 Gb Ex tb IIIC T80°C Db | LED | I | 1x9 1x18 | 582 1156 | 3000~5700 | 2.5 |
II | 2x9 2x18 | 1165 2312 | 6 |
Rated voltage/frequency | Inlet thread | Cable outer diameter | Emergency charging time | Emergency starting time | Emergency lighting time | Degree of protection | Anti corrosion grade |
---|---|---|---|---|---|---|---|
220V/50Hz | G3/4 | Φ10~Φ14mm | 24h | ≤0.3s | ≥90min | IP66 | WF2 |
Product Features
1. Aluminum alloy die-casting shell, high-speed shot peening, high voltage electrostatic spraying on the surface, corrosion resistance and anti-aging;
2. Exposed stainless steel fasteners with high anti-corrosion performance;
3. High strength tempered glass transparent tube, with high light transmittance, has passed strict impact test and thermal shock test, with reliable explosion-proof performance;
4. The grid type protective screen is set, and the surface is sprayed with high-quality carbon steel after galvanizing for double anti-corrosion;
5. Equipped with well-known brand fluorescent tubes, with long service life and high luminous efficiency;
6. The luminaire is equipped with a wiring chamber and a special terminal block, which can be directly installed by the user without the need for another junction box, which is convenient and fast;
7. Modular plug-in design, just loosen the end cover and pull out the core to replace the lamp tube;
8. The LED series light source adopts the latest generation of maintenance free energy-saving LED tubes, which are characterized by long service life, long-term maintenance free, high efficiency and energy saving, wide voltage range, etc;
9. Emergency devices can be installed according to user requirements. When the power supply is cut off, the lamps will automatically switch to the emergency lighting state;
10. Steel pipe or cable wiring is acceptable.
Installation Dimensions
Applicable Scope
1. It is applicable to the places in Zone 1 and Zone 2 of explosive gas environment;
2. It is applicable to the places in Zone 21 and 22 of combustible dust environment;
3. Suitable for IIA, IIB and IIC explosive gas environment;
4. Applicable to T1~T6 temperature groups;
5. It is applicable to work and scene lighting in dangerous environments such as petroleum exploitation, oil refining, chemical industry and gas station.