23 An Producător industrial antiexploziv

+86-15957194752 aurorachen@shenhai-ex.com

AdvantagesofVariableFrequencyExplosion-ProofAirConditioners|Caracteristici de performanta

Caracteristici de performanta

Avantajele aparatelor de aer condiționat cu frecvență variabilă rezistente la explozie

Pe măsură ce epoca progresează, aparatele de aer condiționat au trecut de la modelele convenționale la modelele rezistente la explozie, iar frecvența acestor unități avansate a evoluat de asemenea. Dar cum se remarcă aparatele de aer condiționat cu invertor în comparație cu omologii lor tradiționali rezistenti la explozie? De mai jos, ne aprofundăm în mai multe moduri de protecție îmbunătățită ale aparatelor de aer condiționat cu invertor rezistente la explozie, which ensure safer and more efficient operation during everyday use.

aparat de aer condiționat antiexploziv-17

1. Overheat Protection for Indoor Heat Exchangers:

When operating in heating mode, slow fan speeds or clogged filters can hinder heat dissipation from the indoor coil, causing the heat exchanger’s surface temperatura to rise. This scenario not only decreases heating efficiency but may also lead to equipment overheating. Prin urmare, inverter explosion-proof air conditioners incorporate comprehensive overheat protection for indoor heat exchangers. The system restricts compressor frequency increase when room temperature exceeds 53°C; it reduces compressor frequency and operates the outdoor fan motor at low speed when it surpasses 56°C; and it halts the compressor and activates overheat or overload protection when temperatures exceed 65°C. These critical temperature thresholds are monitored and alerted through display panels, lumini indicatoare, and buzzers.

1. Compressor Overcurrent Protection:

To safeguard against excessive operating currents that could damage the compressor’s motor windings, inverter explosion-proof air conditioners are equipped with robust overcurrent protection. During the cooling phase, if the compressor’s current hits 9.6A, the system’s microprocessor triggers a control signal to prevent frequency increase; at 11.5A, it signals to reduce frequency; and at 13.6A, it activates a protective signal to cease the compressor’s operation. Similar protocols apply during the heating phase, with specific current thresholds set at 13.5A, 15.4A, and 18A, respectiv. Each of these critical stages is prominently signaled to the user through display panels, lumini indicatoare, and buzzers for heightened awareness and safety.

Prev:

Următorul:

Obțineți o cotație ?